300A precision Electron Beam Welded Shunt Resistor With 3 terminal

Description

Overview

Designed for high-accuracy current measurement, this 300A precision electron beam welded shunt resistor with 3 terminals offers exceptional stability and low resistance. Ideal for EV battery packs, BMS, and industrial energy storage systems, it ensures reliable performance under heavy load and harsh conditions. Customizable resistance values and mounting options available

electron beam welded shunt

Electrical parameter

ModelLDL1AFMCB1B2
FL3-6918-B-50μΩ69±0.518±0.552±0.57±0.53.0±0.5φ7.0×21×14±0.16±0.15

Electrical parameter

ParameterSpecification
Rated Current300A
Accuracy Class0.2%, 0.5%, 1%, 2%, 5%
T.C.R (ppm/°C)
20℃ ~ 60℃
≤50
Manganese Copper MaterialNational standard 6J12 precision manganese copper
Copper MaterialNational Standard T2 Y2
Operating Temperature-55℃ ~ +170℃

Performance testing

ProjectTest ConditionsResistance Range
Thermal Shock-40℃ to +150℃, 1000 cycles, 15 minutes at each extreme±0.5%R
Short-term Overload2.5 times rated power, lasting 5 seconds±0.5%R
Low Temperature Operation-40℃ for 45 seconds±0.5%R
High Temperature ExposureAt +170℃ for 1000 hours±1%R
Deviation Humidity+85℃, 85%RH, 10% deviation, 1000 hours±0.5%R
Mechanical Shock100 ms, 6 ms duration, 5 pulses±0.5%R
VibrationFrequency sweep 10Hz–2000Hz in 1 minute, 3 directions, 12 hours±1%
Load Life1000 hours at +70°C, 1.5h “on”, 0.5h “off” cycle±0.5%
Moisture-proofMIL-STD-202±0.5%

Applications

The 300A precision electron beam welded shunt resistor with 3 terminals is ideal for accurate current measurement in high-power systems. It is widely used in:

  • 🔋 EV Battery Packs – For monitoring current flow in electric motorcycles, three-wheelers, and compact EVs.

  • Battery Management Systems (BMS) – Ensures precise current sensing and protection in lithium-ion battery systems.

  • ☀️ Energy Storage Systems (ESS) – Supports stable load control and energy monitoring in solar and commercial storage units.

  • 🏭 Industrial Power Equipment – Applied in UPS, inverters, and high-load power modules for current detection.

  • 🚉 Railway and Heavy Equipment – Handles current monitoring in transportation battery systems under demanding conditions.

For more details on technical standards for shunt resistors in BMS and EV systems, refer to the